Criteria

TR severity as determined by echocardiographic quantification of annular diameter

Normal tricuspid valve annulus diameter in adults is 28 mm (± 5 mm) in the 4 chamber view. Significant tricuspid annular dilation is defined by a diastolic diameter of over 40 mm (absolute value) or 21 mm/square meter of body surface area.[2] A correlation exists between tricuspid annulus diameter and TR severity: a systolic tricuspid diameter >3.2 cm or a diastolic tricuspid annulus diameter >3.4 cm are often markers of more significant TR.​[3][Figure caption and citation for the preceding image starts]: Severe tricuspid regurgitation due to annular enlargement. A. Systolic frame from apical 4 chamber view (Mayo Clinic display format with right ventricle on the right). Note tricuspid annular enlargement measuring 4.2 cm and tethering of the tricuspid leaflets leading to failure of coaptation of the tricuspid valve. B. Massive tricuspid regurgitation on Color Doppler. C. Continuous Wave Doppler through the tricuspid valve. Note the dagger-shaped tricuspid regurgitant signal (arrows), consistent with rapid equalization of pressures between right ventricle and right atrium, typical of massive tricuspid regurgitation. D. Pulsed Wave Doppler of the hepatic veins demonstrates late systolic flow reversals consistent with severe tricuspid regurgitation.From the collection of Sorin V. Pislaru, Mayo Clinic [Citation ends].com.bmj.content.model.Caption@63d69e64

Vena contracta width quantification of TR

Severe TR is defined as vena contracta (the narrowest central flow region of a jet that occurs at, or just downstream to, the orifice of a regurgitant valve) width >0.7 cm. In case of multiple jets, the respective values of the vena contracta width are not additive.​[3][Figure caption and citation for the preceding image starts]: Severe tricuspid regurgitation due to carcinoid valvular disease. A. Systolic frame from mid-esophageal 4 chamber view. Note thickened tricuspid leaflets, but also retracted and thickened chordae, typical of advanced carcinoid valvular disease (arrows). The right ventricle and right atrium are enlarged. The atrial septum is deviated to the left, demonstrating right atrial pressure is higher than left atrial pressure (asterisk). B. Color Doppler demonstrating severe tricuspid regurgitation. Vena contracta measured 1.2 cm, consistent with the coaptation gap on 2D images and virtually free flow between the right ventricle and right atrium.From the collection of Sorin V. Pislaru, Mayo Clinic [Citation ends].com.bmj.content.model.Caption@7dda6b44

Echocardiography Doppler quantification of TR

Proximal isovelocity surface area (PISA) radius of 1 mm to 4 mm suggests mild TR, 5 mm to 8 mm moderate TR, >9 mm severe TR, at an aliasing velocity setting (the velocity of a flow that exceeds the color Doppler scale) of approximately 40 cm/sec. An effective regurgitant orifice area ≥40 mm² or a regurgitant volume of ≥45 mL indicates severe TR. The PISA method may underestimate the severity of TR by 30%, and is also less accurate in eccentric jets.[3]​ Quantification is important, as there is great variability in interpreting TR severity based on semiquantitative indexes alone.[4]

Doppler color flow jet quantification of TR

The color flow area of the regurgitant jet is not recommended to quantify the severity of TR. Color flow imaging should only be used for diagnosing TR. A more quantitative approach is required when more than a small central TR jet is observed.​[3]

Inferior vena cava flow reversal quantification of TR

The systolic hepatic flow reversal is specific for severe TR. It represents the strongest additional parameter for evaluating the severity of TR.[3]​ Concomitant presence of atrial fibrillation or right ventricular pacing reduces the specificity of this finding.[Figure caption and citation for the preceding image starts]: Severe tricuspid regurgitation due to annular enlargement. A. Systolic frame from apical 4 chamber view (Mayo Clinic display format with right ventricle on the right). Note tricuspid annular enlargement measuring 4.2 cm and tethering of the tricuspid leaflets leading to failure of coaptation of the tricuspid valve. B. Massive tricuspid regurgitation on Color Doppler. C. Continuous Wave Doppler through the tricuspid valve. Note the dagger-shaped tricuspid regurgitant signal (arrows), consistent with rapid equalization of pressures between right ventricle and right atrium, typical of massive tricuspid regurgitation. D. Pulsed Wave Doppler of the hepatic veins demonstrates late systolic flow reversals consistent with severe tricuspid regurgitation.From the collection of Sorin V. Pislaru, Mayo Clinic [Citation ends].com.bmj.content.model.Caption@dd267aa

Use of this content is subject to our disclaimer