IEEE Draft Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V - Amendment 1

This amendment will address items discovered by users 1 related to discrepancies with other industry standards: Harmonize pollution levels for normal service condition. Further define requirements for capacitive switching class C0. Clarify required electrical service capability. Improve definition of interrupting time. Implement requirements from IEEE C37.11 which are more properly in C37.04 Align material imported from NEMA SG-4 with current industry practices.

Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Status
Active PAR
PAR Approval
2021-12-08

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Working Group
HVCB/C37.04 - C37.04 - Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
John Webb

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


PC37.04
Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V

This standard applies to ac high-voltage circuit breakers with rated nominal voltage above 1000 V. It establishes a rating structure, preferred ratings, construction and functional component requirements. This standard encompasses the following: - Three pole circuit breakers used in three-phase systems - Single pole circuit breakers used in single-phase systems - Attachments for these circuit breakers, such as bushings, current transformers, interlocks, shunt trips, etc., and auxiliary equipment sold with the circuit breakers such as closing relays and structural steel supports. This standard does not cover circuit breakers used at frequencies other than 50 Hz or 60 Hz or generator circuit breakers that are covered in IEC/IEEE Std 62271-37-013.

Learn More About PC37.04

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.04-2018
IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V

The rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types, is covered in this standard. Preferred ratings are also provided. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A, 1200 A, 2000 A, 3000 A, and 4000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, insulation capability (formerly dielectric withstand voltages), short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. Generator circuit breakers are covered by IEC/IEEE Std 62271-37-013.

Learn More About C37.04-2018

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C37.04-1999
IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers

This standard covers the rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types having the preferred ratings as listed in ANSI C37.06-1997. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A,1200 A, 2000 A, and 3000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, dielectric withstand voltages,short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. This standard does not cover generator circuit breakers, which are covered in IEEE Std C37.013-1997.

Learn More About C37.04-1999

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.