Withdrawn Standard. Withdrawn Date: Oct 25, 1996. The most common sheath-bonding systems now in use, and the methods of calculating sheath voltages and currents, are described. The concern is particularly with three-phase systems operating at 60 kV and above, with the neutral grounded directly or through an impedance. Bonding methods and sheath voltage limiters are covered. Effects on parallel telephone and control cables are considered.
- Standard Committee
- PE/IC - Insulated Conductors
- Status
- Inactive-Withdrawn Standard
- Superseded by
- 575-2014
- Board Approval
- 1986-03-13
- History
-
- Withdrawn:
- 1996-10-25
- ANSI Approved:
- 1986-08-07
- Published:
- 1987-11-25
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/IC - Insulated Conductors
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
P575
Guide for Application of Sheath-Bonding Methods for Single-Conductor Cables and the Calculation of Induced Voltages and Currents in Cable Sheaths
This guide describes the most common special sheath-bonding systems in use on high-voltage, single-conductor, shielded power cables and methods of calculating sheath voltages and currents, particularly as applied to three-phase systems, with the cable neutral grounded directly or as part of a special bonding system as described in the guide. The guide reflects the latest industry practices.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
575-2014
IEEE Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5 kV through 500 kV
The most common shield/sheath-bonding systems now in use on medium through extra high-voltage (5 kV to 500 kV) single-conductor shielded power cables and the methods of calculating the corresponding shield/sheath voltages and currents, when the cables are operated as part of a three-phase system, with the neutral grounded directly or through an impedance, are described in this guide.