Abstract:

This is a standard for developing data related to the seismic capabilities of relays. This standard compliments ANSI/IEEE Std 344-1975, Recommended Practices for Seismic ...Show More
Scope:This standard specifies the procedures t o be used in the seismic testing of relays used in power system facilities. The standard is concerned with the determination of t...Show More
Purpose:The purpose of this standard is to establish procedures for determining the seismic capabilities of protective and auxiliary relays. These procedures employ what has been...Show More

Abstract:

This is a standard for developing data related to the seismic capabilities of relays. This standard compliments ANSI/IEEE Std 344-1975, Recommended Practices for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations, which provides general guidelines for developing data related to seismic qualification of equipment used in nuclear generating plants. Data must be developed by testing rather than analytical means since protective relays fall into the category of complex devices as described in Section 5 of ANSI/IEEE Std 344-1975; however, analysis may be used in data reduction, in reconciling response spectra, in justifying methods ...
Scope:
This standard specifies the procedures t o be used in the seismic testing of relays used in power system facilities. The standard is concerned with the determination of the seismic fragility level of relays and also gives recommendations for proof testing.
Purpose:
The purpose of this standard is to establish procedures for determining the seismic capabilities of protective and auxiliary relays. These procedures employ what has been called fragility testing in ANSI/IEEE Std 344-1975, Recommended Practices for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations. In order to define the conditions for fragility testing of relays, parameters in three separate areas must be specified. In general they are: (l) The electrical settings and inputs to the relay, and other information to define its conditions during the test. (2) The change in state, deviation in operating characteristics or toleranc...
Date of Publication: 28 April 1978