Abstract:
Goals for the design of electrical systems that include both linear and nonlinear loads are established in this recommended practice. The voltage and current waveforms th...Show MoreScope:This recommended practice establishes goals for the design of electrical systems that include both linear and nonlinear loads. The voltage and current waveforms that may ...Show More
Purpose:This recommended practice is to be used for guidance in the design of power systems with nonlinear loads. The limits set are for steady-state operation and are recommende...Show More
Metadata
Abstract:
Goals for the design of electrical systems that include both linear and nonlinear loads are established in this recommended practice. The voltage and current waveforms that may exist throughout the system are described, and waveform distortion goals for the system designer are established. The interface between sources and loads is described as the point of common coupling and observance of the design goals will reduce interference between electrical equipment.This recommended practice addresses steady-state limitations. Transient conditions exceeding these limitations may be encountered. This document sets the quality of power that is to be provided at the ...
Scope:
This recommended practice establishes goals for the design of electrical systems that include both linear and nonlinear loads. The voltage and current waveforms that may exist throughout the system are described, and waveform distortion goals for the system designer are established. The interface between sources and loads is described as the point of common coupling and observance of the design goals will minimize interference between electrical equipment. This recommended practice addresses steady-state limitations. Transient conditions exceeding these limitations may be encountered. This document sets the quality of power that is to be provided at the poin...
Purpose:
This recommended practice is to be used for guidance in the design of power systems with nonlinear loads. The limits set are for steady-state operation and are recommended for “worst case” conditions. Transient conditions exceeding these limits may be encountered. In any case, the limit values given in this document are recommendations and should not be considered binding in all cases. Because of the nature of the recommendations, some conservatism is present that may not be necessary in all cases. This recommended practice should be applied at interface points between system owners or operators and users in the power system. The limits in this recommended p...