Loading [a11y]/accessibility-menu.js
C57.12.10-2010 - IEEE Standard Requirements for Liquid-Immersed Power Transformers | IEEE Standard | IEEE Xplore

C57.12.10-2010 - IEEE Standard Requirements for Liquid-Immersed Power Transformers


Abstract:

This standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safe...Show More
Scope:This voluntary consensus standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, intercha...Show More

Abstract:

This standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered and to assist in the proper selection of such equipment. This document is a product standard that covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz, liquid-immersed power transformers and autotransformers. Such powertransformers may be remotely or integrally associated with either primary switchgear or substations, or both, for step-down or step-up purposes and base rated as follows: 833 kVA and above single-phase, 750 kVA and above three-phase. This standard applies to all liquid-immersed power transformers and autotransformers that do not belong to the following types of apparatus: instrument transformers, step voltage and induction voltage regulators, arc-furnace transformers, rectifier transformers, specialty transformers, grounding transformers, m...
Scope:
This voluntary consensus standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered and to assist in the proper selection of such equipment. This document is a product standard that covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz, liquid-immersed power transformers and autotransformers. Such power transformers may be remotely or integrally associated with either primary switchgear or substations, or both, for step-down or step-up purposes and base rated as follows: 833 kVA and above single-phase, 750 kVA and above three-phase. This standard applies to all liquid-immersed power transformers and autotransformers that do not belong to the following types of apparatus: a) Instrument transformers b) Step voltage and induction voltage regulators c) Arc-furnace transformers d) Rectifier transformers e) Specialty transfo...
Date of Publication: 06 January 2011
Electronic ISBN:978-0-7381-6444-1
Persistent Link: https://ieeexplore.ieee.org/servlet/opac?punumber=5685834

Subscription Options - Standards

References

References is not available for this document.