Loading [a11y]/accessibility-menu.js
1542-2007 - IEEE Guide for Installation, Maintenance, and Operation of Irrigation Equipment Located Near or Under Power Lines | IEEE Standard | IEEE Xplore

1542-2007 - IEEE Guide for Installation, Maintenance, and Operation of Irrigation Equipment Located Near or Under Power Lines


Abstract:

The guide is based on industry practices, and guidelines for installation, maintenance and operation of irrigation equipment near or under power lines as they pertain to ...Show More
Scope:The guide is based on industry practices and presents guidelines for installation, maintenance, and operation of irrigation equipment near or under power lines as they pe...Show More
Purpose:The guide is intended for designers, installers, and operators of the irrigation equipment, as well as electric power utilities whose lines are located near or above the ...Show More

Abstract:

The guide is based on industry practices, and guidelines for installation, maintenance and operation of irrigation equipment near or under power lines as they pertain to minimum distance to energized conductors and proper grounding to minimize nuisance shocks are presented. A variety of conditions in general terms is covered in this guide. Specific recommendations are made for the type of irrigation systems and power line parameters most commonly found.
Scope:
The guide is based on industry practices and presents guidelines for installation, maintenance, and operation of irrigation equipment near or under power lines as they pertain to minimum distance to energized conductors and proper grounding to minimize nuisance shocks. The guide covers a variety of conditions in general terms. Specific recommendations are made for the type of irrigation systems and power line parameters most commonly found.The guide is based on industry practices and presents guidelines for installation, maintenance, and operation of irrigation equipment near or under power lines as they pertain to minimum distance to energized conductors an...
Purpose:
The guide is intended for designers, installers, and operators of the irrigation equipment, as well as electric power utilities whose lines are located near or above the irrigation systems. General information is provided on installation, maintenance, and operation of irrigation equipment as it relates to safety due to the presence of electric power lines. The following parameters are considered: a) Distance to energized conductors during installation b) Proper grounding to minimize nuisance shocks c) Distance between irrigation nozzle and power line conductors during operation of the irrigation system The recommended minimum conductor-to-nozzle distance is ...
Date of Publication: 12 February 2008
Electronic ISBN:978-0-7381-5699-6
Persistent Link: https://ieeexplore.ieee.org/servlet/opac?punumber=4451079

Subscription Options - Standards

References

References is not available for this document.