Abstract:

Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, ...Show More

Abstract:

Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket and armor. The recommendations apply to cables rated for voltages not exceeding 3 kV or 5 kV and for ambient temperatures not exceeding 205 degrees Fahrenheit or below 14 degrees Fahrenheit. Conductors, insulation, assembly, jacket, armor, requirements for testing by the manufacturer, and cable ampacity ratings are covered.
Date of Publication: 14 August 1992
Electronic ISBN:978-1-5593-7194-0
Persistent Link: https://ieeexplore.ieee.org/servlet/opac?punumber=4337

Subscription Options - Standards

References

References is not available for this document.